Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Arq. bras. med. vet. zootec. (Online) ; 72(6): 2233-2238, Nov.-Dec. 2020. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1142293

ABSTRACT

Um filhote de porquinho-da-índia (Cavia porcellus) foi recebido para atendimento após histórico de ataque por cão. Na avaliação física, observou-se edema, dor e crepitação em membro pélvico direito, sugestivo de fratura. Na avaliação radiográfica, confirmou-se fratura Salter-Harris tipo I em epífise distal da tíbia. A resolução cirúrgica escolhida foi a associação de pino transarticular e coaptação externa com tala de Altman. O paciente teve acompanhamento radiográfico semanal e obteve alta médica no 35o dia de pós-cirúrgico, quando se observou consolidação com completo remodelamento ósseo.(AU)


A guinea pig (Cavia porcellus) cub presented edema, pain, and crepitus in the right pelvic limb after being attacked by a dog. Radiographic examination revealed Salter-Harris type 1 fracture on the distal region of the tibia. The surgery technique to correct the fracture involved an association of transarticular pinning and external coaptation with Altman splint. After surgery, radiographs of the patient were performed weekly and on the 35th post-surgery day, the bone was completely remodeled and healed, and the animal was dismissed.(AU)


Subject(s)
Animals , Rodentia/injuries , Bone Nails/veterinary , Fracture Fixation, Intramedullary/veterinary , Tibial Fractures/veterinary , Epiphyses/injuries
2.
Pesqui. vet. bras ; 38(10): 1909-1912, out. 2018. ilus
Article in English | LILACS, VETINDEX | ID: biblio-976373

ABSTRACT

Technological and tissue engineering have enabled available, biologically inert, and low cost materials to be considered as viable alternatives in the surgical treatment of long bone fractures in birds. The aim of this study was to microscopically analyse osteotomized humerus of birds following the insertion of solid laser-sintered polyamide 12 rods in order to detect foreign body reaction and, thus, verify the bioinert property of the material in the bone fracture environment. Polyamide 12 intramedullary rods were inserted into the osteotomized humerus of 10 birds (white Plymouth Rock) and blocked using 2mm diameter cortical screws of varying lengths. The birds were operated at 60 days of age and monitored post-operatively for three months. Animals were euthanized at 150 days old and samples of the operated humerus collected for immunohistochemistry, light and scanning electron microscopy analysis. Results show bone consolidation without rejection of the implant and absence of inflammatory cells. Vascular Endothelial Growth Factor (VEGF) was expressed in the endothelial cells of the blood vessels at the site of the newly formed bone surrounding the implant, indicative of local angiogenesis. There was no bone growth on the surface of the rod; however, the implant did not interfere with the circumjacent bone repair. Thus, the findings of this study corroborate with the literature in characterizing polyamide as a bioinert material and, under the studied conditions, it can be concluded that polyamide 12 intramedullary rod is biocompatible and provides adequate bone consolidation in humeral fractures with no signs of rejection.(AU)


Com o desenvolvimento tecnológico e crescimento da engenharia de tecidos, o uso de materiais disponíveis, bioinertes e debaixo custo pode ser alternativa viável para o tratamento cirúrgico de fraturas em ossos longos nas aves. O objetivo do estudo foi realizar avaliação microscópica óssea após a implantação de haste maciça de poliamida, implantada em úmeros osteotomizados de galinhas para detectar reação do tipo corpo estranho, verificando a propriedade "bioinerte" do material no ambiente de fratura óssea. Foram utilizados 10 galos (Plymouth rock branca) e implantou-se a haste perfazendo o bloqueio das mesmas com parafusos corticais de 2 mm de diâmetro com comprimentos de acordo com a necessidade. As aves foram operadas aos 60 dias de vida e o acompanhamento pós-operatório ocorreu por três meses. Após a eutanásia, foram realizadas coletas do úmero operado (local de consolidação óssea) paraexame histopatológico, imuno-histoquímico e de microscopia eletrônica de varredura. Os resultados demonstraram consolidação óssea, sem presença de rejeição do material, com ausência de células inflamatórias. A neoformação óssea ao redor do implante expressou VEGF (fator de crescimento endotelial vascular) nas células endoteliais dos vasos sanguíneos caracterizando angiogênese no local. Na região de interface de tecido ósseo com a poliamida não foram observadas micro fraturas. Não houve crescimento ósseo na superfície da haste, porém a mesma não atrapalhou o reparo ósseo circunjacente. Assim, esse estudo corrobora com a literatura caracterizando a poliamida como um material bioinerte, e nas condições estudadas pode-se concluir que o uso da haste intramedular de poliamida 12 proporcionou consolidação óssea nesse modelo biológico nesse tipo de fratura, não havendo indícios de induzir rejeição.(AU)


Subject(s)
Animals , Biocompatible Materials , Biocompatible Materials/adverse effects , Chickens , Fracture Fixation, Internal/veterinary , Fracture Fixation, Intramedullary/veterinary , Host vs Graft Reaction , Nylons
3.
Pesqui. vet. bras ; 37(12): 1474-1478, dez. 2017. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-895384

ABSTRACT

Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84®5,55o) e T1 (111,22o®3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6®4,70o e T1=110,06®10,61o, p<0,05) quanto no grupo HIB (T0=126,43®5,87o e T1=116,87®8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3®74,46N/mm) em relação ao grupo HIB (586,7®44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.(AU)


Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84®5.55o) and T1 (111.22o®3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6®4.70o e T1=110.06®10.61o, p<0.05) and IN group (T0=126.43®5.87o e T1=116.87® 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3®74.46N/mm) compared to IN group (586.7®44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.(AU)


Subject(s)
Animals , Dogs , Osteotomy/veterinary , Prostheses and Implants/veterinary , Bone Plates/veterinary , Fracture Fixation, Intramedullary/veterinary , Hip Dysplasia, Canine/therapy , Hip Fractures/veterinary , Orthopedic Procedures/veterinary
4.
Arq. bras. med. vet. zootec. (Online) ; 69(4)jul.-ago. 2017. ilus
Article in English | LILACS, VETINDEX | ID: biblio-876503

ABSTRACT

The aim of this study was to evaluate the use of polyamide 12 intramedullary rods in osteotomized humerus in cockerels (White Plymouth Rock) and analyze, by radiography and histopathology, bone consolidation and the formation of bone callus. Ten cockerels were subjected to transverse osteotomy of the right humeral diaphysis followed by the insertion of polyamide 12 locked rods, with two nails in each bone fragment. Radiographies obtained at the immediate pre and post-operative period, and every 7 days for 3 months revealed no perioperatory complications. Radiography revealed a radiopaque bone callus between the 4th and 5th week post-surgery. Histopathology detected an amphophylic material (polyamide 12 rod) in the intramedullary region and the proliferation of highly vascularized connective tissue between the rod and the cortical bone. This connective tissue was highly cellular with differentiation into osteoblasts. The collagen fibers varied from loose to dense and a differentiated bone matrix, containing osteocytes in gaps and the development of bone marrow, was also observed; indicating the formation of a bone callus without signs of implant rejection. The polyamide 12 intramedullary rod was effective in the stabilization of the fractures used in this experimental model, with no rejection reaction for at least 90 days.(AU)


O presente estudo teve como objetivo avaliar a implantação de hastes intramedulares de poliamida 12, em úmeros osteotomizados de galos (Plymouth Rock Branca), bem como avaliar a consolidação óssea, por meio da verificação da formação de calo ósseo, analisando exames radiográficos e histopatológicos. Os galos foram submetidos à osteotomia transversa da diáfise do úmero direito, sendo implantadas posteriormente as hastes de poliamida 12 bloqueada com dois parafusos em cada fragmento ósseo. Após o procedimento cirúrgico, foram realizadas radiografias nos momentos pré e pós-operatório imediato e, posteriormente, a cada sete dias, durante três meses, até a realização da eutanásia. Não houve complicações perioperatórias. Ao exame radiográfico, os animais apresentaram formação de calo ósseo radiopaco entre a quarta e quinta semanas de pós-operatório. Ao exame histopatológico, foi possível notar, em todos os animais, presença de material anfofílico (haste de poliamida 12) ocupando a região intramedular óssea, e entre a haste e as corticais ósseas, proliferação de tecido conjuntivo altamente vascularizado. Tal tecido apresentou-se altamente celular com diferenciação em osteoblastos. Notaram-se também fibras colágenas, variando de aspecto frouxo a denso, e observou-se formação de matriz óssea diferenciada com osteócitos em lacunas e formações de medula óssea, denotando formação de calo ósseo sem sinais de rejeição do implante. A haste intramedular de poliamida 12 foi eficaz para estabilização das fraturas utilizando-se esse modelo experimental, sem reação de rejeição pelo período de 90 dias.(AU)


Subject(s)
Animals , Chickens/surgery , Fracture Fixation, Intramedullary/veterinary , Fractures, Bone/surgery , Humerus/injuries , Nylons
5.
Ciênc. rural ; 32(2): 269-273, mar.-abr. 2002. graf
Article in Portuguese | LILACS | ID: lil-349501

ABSTRACT

Avalia-se, clínica e comparativamente, o aparelho de fixaçäo externa e pinos intramedulares, quanto ao tempo de recuperaçäo das funçöes normais e deambulaçäo de cäes sadios. Foram utilizados 16 cäes sadios separados em dois grupos experimentais de oito animais. No primeiro grupo, os cäes foram submetidos à aplicaçäo de um aparelho de fixaçäo externa e, no segundo grupo, submetidos à inserçäo de dois pinos intramedulares na tíbia esquerda. Os aparelhos de fixaçäo externa foram retirados após 30 dias de avaliaçäo clínica. Observou-se que os cäes com fixadores externos tiveram retorno funcional em média de 17,3 dias, enquanto os submetidos à inserçäo intramedular tiveram retorno aos 4,2 dias. Com esses resultados, conclui-se que o uso de pinos intramedulares tem menor interferência na deambulaçäo em relaçäo ao aparelho de fixaçäo externa.


Subject(s)
Animals , Dogs/injuries , External Fixators , Fracture Fixation, Intramedullary/veterinary , Tibial Fractures/therapy , Tibial Fractures/veterinary , Bone Nails/veterinary
6.
Ciênc. rural ; 28(1): 77-82, jan.-mar. 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-246406

ABSTRACT

As fraturas diafisárias de tíbia possuem alta prevalência na espécie canina. Este estudo visa avaliar o uso de pinos intramedulares de Steinmann na reduçäo destas fraturas. Dez cäes de idade, sexo e peso variados, portadores de fratura de tíbia foram submetidos à osteossíntese mediante inserçäo de dois pinos intramedulares de Steinmann pela crista tibial e em seguida, avaliados clinicamente e radiograficamente durante o período de cicatrizaçäo óssea. Diante dos resultados, demonstrou-se a versatilidade e eficiência do método.


Subject(s)
Animals , Male , Female , Dogs/injuries , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/veterinary , Tibial Fractures/therapy , Tibial Fractures/veterinary , Bone Nails , Bone Nails/veterinary
7.
Arq. bras. med. vet. zootec ; 46(3): 253-62, jun. 1994. ilus
Article in Portuguese | LILACS | ID: lil-240189

ABSTRACT

Dois grupos de sete gatos sem raça definida, com idade entre 6 meses e 7 anos e peso de 0,75 e 3,30 kg, foram submetidos a fratura completa, transversa, diafisária da tíbia. Após reduçäo, a fratura foi estabilizada por quatro pinos de transfixaçäo percutânea, imobilizados por resina acrílica nos animais do grupo I. Nos do grupo II, a fratura foi reduzida e alinhada com um pino intramedular antes de técnica da transfixaçäo. A evoluçäo foi avaliada por exames físicos e radiográficos. O método empregado no grupo II permitiu reduçäo e alinhamento mais eficientes, conferindo maior estabilidade, embora o tempo para consolidaçäo das fraturas tenha sido mais prolongado que nos animais do grupo I


Subject(s)
Animals , Cats/surgery , Camurati-Engelmann Syndrome/veterinary , Fracture Fixation, Intramedullary/veterinary , Tibial Fractures/veterinary , Bone Nails/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL